Why Is Maintenance Important For Water Purifier Solenoid Valve

RO service near me in Meerut

The solenoid valve in the water purifier gets electromagnetically to control input water flow. The input water renters the water purifier when the machine is on. The solenoid valve opens to let in the water. The valve closes and shuts off the water flow when it gets turned off.

The purpose of the solenoid is to avoid water overflow. The solenoid valves are pretty robust in handling heavy water flow. They last for many years. 

Advantages of a Solenoid Valve

The solenoid valves can get used in a variety of system applications. Of course, it gets used in water purifiers too. A solenoid valve from RO service near me in Meerut efficiently controls the control of liquids and gases. 

Wiring is not a requirement. The valve in water purifiers with technologies like reverse osmosis stops the water from penetrating the membrane pressure of the tank is about two-thirds that of the incoming water. 

They are inexpensive and function more efficiently compared to other valves. The solenoid valves can work to the fullest in a short time. 

When a Solenoid Valve Malfunctions

Solenoid valves become dirty and contaminated over time. Contaminants can accumulate in the core tubes and slow down the water flow. Proper voltage is essential for the valves to work properly. The nominal voltage will not open or close the valve, resulting in excessive noise. It will cause the solenoid valve to wear faster.

Excessive moisture causes the solenoid valve to malfunction early on. The humidity in the valve can get removed with the servicing from a water purifier service in Meerut. Otherwise, the solenoid enclosure with moisture will cause the coil to malfunction. 

It is best to consult experts about the selection and sizing of the valves. The valve of the right size allows the water purifier to function at its highest efficiency. It would mean that you will save money and have fewer maintenance calls.

How to Make the Solenoid Valve Working Again

The practical solution to get the solenoid valve up and working again is to clean it. If not, it could lead to improper voltages, improper opening and closing, corrosion, and burn-out coils. Consult with the service provider and check if the recommended voltage to the humidifier and valve is correct.

Excessive fluid pressure differentials between the outlet and the valve’s inlet cause a clack or buzz when it is working. Alert the service provider about this problem, who will check the fluid pressure to make the correct adjustments.

A leaky valve means the solenoid is stuck open or partially open. That could have happened for several reasons. Such a situation leads to water leakage. Some of the common causes are a plunger valve not closing completely, cracks in the plunger valve seat, degraded O-rings, or internal contaminants build-up.

To Clean Or To Replace?

The debris collected in the solenoid valve seat can get cleaned and returned to the humidifier. One can reduce the possibility of corrosion by soaking the purifier valve in vinegar and water. Proactive maintenance is much more beneficial for the solenoid valve, just like any other machine. 

It extends the life of the valve. Expert servicing from experts will address the issue and provide proactive measures to bar it from reoccurring. 


Role of Water Supply 

Water with high contamination or TDS (Total Dissolved Solids) can clog the solenoid valve. A filter installation before the valve will reduce the number of particles reaching the valve. Maintenance ensures that the solenoid valve operates at an optimal level. 

Inspection Process 

The service provider will check the components of the valve by removing the top nut. Then they check for sediments. Next, they assess if the spring assembly can move freely in the tube. Next, check the seals and O-rings for any possible contamination or wear. Replace the damaged or worn components.

Remember These Checkpoints before Replacing the Solenoid Valve 

 Before replacing the solenoid valve, ensure you know the valve’s rating and the water purifier’s power supply. Such factors must be the same. Otherwise, the water purifier will not give the required water flow and supply.

For instance, for a 45V power supply, one should get a 45V solenoid pump. If it is not, then the solenoid pump will get dysfunctional after a while. Install the solenoid valve after the sediment filter to avoid choking by the impurities.

You May Also Like

About the Author: Harry Brown

My name is Harry Brown.I am living in Delware United States.I have completed my degree in Marketing from the University of California.I have 4 years experience in different multinational organizations. Currently I am working in TheBestGossip as Digital Marketing Expert. TheBestGossip is one of the best companies in United States for providing Digital Marketing Services in Casino.

Leave a Reply